{"id":17660,"date":"2024-08-12T17:37:12","date_gmt":"2024-08-12T15:37:12","guid":{"rendered":"https:\/\/www.stirepair.com\/fimer-r-series-error-codes\/"},"modified":"2026-03-18T16:05:13","modified_gmt":"2026-03-18T15:05:13","slug":"fimer-r-series-error-codes","status":"publish","type":"page","link":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/","title":{"rendered":"Fimer R Series Error Codes"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"17660\" class=\"elementor elementor-17660 elementor-17657\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4c84c36 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4c84c36\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-35c2de6\" data-id=\"35c2de6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-8f60fde elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8f60fde\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-536eabd\" data-id=\"536eabd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-47d76f3 elementor-invisible elementor-widget elementor-widget-image\" data-id=\"47d76f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;zoomIn&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"487\" height=\"683\" src=\"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/FIMER-serie-R-Armadio-rack.webp\" class=\"elementor-animation-grow attachment-large size-large wp-image-17666\" alt=\"FIMER R Series Rack Cabinet\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-8c958b3\" data-id=\"8c958b3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4a10430 elementor-invisible elementor-widget elementor-widget-image\" data-id=\"4a10430\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;bounceIn&quot;,&quot;_animation_delay&quot;:1300}\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"788\" height=\"670\" src=\"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/FIMER-serie-R-Power-Block.webp\" class=\"elementor-animation-grow attachment-large size-large wp-image-17668\" alt=\"FIMER R Series IGBT Power Stack\" srcset=\"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/FIMER-serie-R-Power-Block.webp 788w, https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/FIMER-serie-R-Power-Block-768x653.webp 768w\" sizes=\"(max-width: 788px) 100vw, 788px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d49fcb elementor-widget__width-initial elementor-hidden-mobile elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"9d49fcb\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;bounceIn&quot;,&quot;_animation_delay&quot;:1300}\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R400 - R500 - R800 - R1000<br>R1200 - R1500TLI - R2000TLI<br>R2250TLI - R2500TLI - R3000TLI<br>R3750TLI - R4000TLI - R4500TLI<br>R5000TLI - R6000TL - R6800TL<br>R7500TL - R5515TL - R6615TL<br>R7715TL - R8815TL - R10015TL<br>R11015TL - R3015TL - R12715TL<br>R14015TL - R15015TL - R18615TL<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-654923c elementor-hidden-desktop elementor-hidden-tablet elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"654923c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-1317ec5\" data-id=\"1317ec5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-97bcba3 elementor-widget__width-initial elementor-invisible elementor-widget elementor-widget-heading\" data-id=\"97bcba3\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;bounceIn&quot;,&quot;_animation_delay&quot;:1300}\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R400 - R500 - R800 - R1000 - R1200 - R1500TLI - R2000TLI - R2250TLI - R2500TLI - R3000TLI - R3750TLI - R4000TLI - R4500TLI - R5000TLI - R6000TL - R6800TL - R7500TL - R5515TL - R6615TL - R7715TL - R8815TL - R10015TL - R11015TL - R3015TL - R12715TL - R14015TL - R15015TL - R18615TL<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dc683fd elementor-section-height-min-height elementor-section-items-bottom elementor-section-content-bottom elementor-section-boxed elementor-section-height-default\" data-id=\"dc683fd\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-537cdb9\" data-id=\"537cdb9\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a1a8605 elementor-invisible elementor-widget elementor-widget-elementskit-heading\" data-id=\"a1a8605\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;zoomIn&quot;,&quot;_animation_tablet&quot;:&quot;zoomIn&quot;,&quot;_animation_mobile&quot;:&quot;zoomIn&quot;}\" data-widget_type=\"elementskit-heading.default\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" ><div class=\"ekit-heading elementskit-section-title-wraper text_left   ekit_heading_tablet-   ekit_heading_mobile-\"><h1 class=\"ekit-heading--title elementskit-section-title \">FIMER R SERIES<\/h1><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a04d9f elementor-icon-list--layout-inline elementor-align-start elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"0a04d9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items elementor-inline-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/stirepair.com\/sti_repair\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Home<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/stirepair.com\/riparazione-inverter\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chevron-right\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Error Code  <\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/stirepair.com\/codici_errore\/\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chevron-right\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Photovoltaic<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\">\n\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chevron-right\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">FIMER R Series<\/span>\n\t\t\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c0ebdb7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c0ebdb7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1474fbb elementor-invisible\" data-id=\"1474fbb\" data-element_type=\"column\" data-e-type=\"column\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;animation&quot;:&quot;fadeInDown&quot;,&quot;animation_mobile&quot;:&quot;none&quot;}\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7412cb4 elementor-widget elementor-widget-text-editor\" data-id=\"7412cb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Listed below are the requirements for initial action on a failed inverter. Before proceeding with any operation: A) Verify that the model is correct; B) Carefully follow all instructions provided in the manufacturer&#8217;s operation and maintenance manual; C) Ensure that the intervention is carried out by trained personnel; D) Since this is a photovoltaic inverter with a DC input that is always live, <strong>strictly observe all applicable safety regulations<\/strong>.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7da7673 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7da7673\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ad95491\" data-id=\"ad95491\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8cfde6b elementor-invisible elementor-widget elementor-widget-elementskit-heading\" data-id=\"8cfde6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;zoomIn&quot;,&quot;_animation_tablet&quot;:&quot;fadeInLeft&quot;,&quot;_animation_mobile&quot;:&quot;zoomIn&quot;}\" data-widget_type=\"elementskit-heading.default\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" ><div class=\"ekit-heading elementskit-section-title-wraper text_center   ekit_heading_tablet-   ekit_heading_mobile-\"><h2 class=\"ekit-heading--title elementskit-section-title \">Alarms, Errors and Warnings<\/h2><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-730248a elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"730248a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c105b46 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c105b46\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ee000bd\" data-id=\"ee000bd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c87dbbc elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c87dbbc\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-0f211a5\" data-id=\"0f211a5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-02c3478 elementor-widget elementor-widget-elementskit-table\" data-id=\"02c3478\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;search_placeholder&quot;:&quot;Type Here To Search...&quot;,&quot;info_text&quot;:&quot;Showing _START_ to _END_ of _TOTAL_ entries&quot;,&quot;entries_text&quot;:&quot;Show _MENU_ entries&quot;}\" data-widget_type=\"elementskit-table.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"ekit-wid-con\" >\n<div class=\"ekit_table display  ekit_table_data_type-custom\"\n\tdata-settings=\"{&quot;fixedHeader&quot;:false,&quot;search&quot;:true,&quot;search_placeholder&quot;:&quot;Type Here To Search...&quot;,&quot;responsive&quot;:true,&quot;pagination&quot;:true,&quot;button&quot;:false,&quot;entries&quot;:true,&quot;info&quot;:true,&quot;info_text&quot;:&quot;Showing _START_ to _END_ of _TOTAL_ entries&quot;,&quot;entries_text&quot;:&quot;Show _MENU_ entries&quot;,&quot;ordering&quot;:true,&quot;searchIcon&quot;:&quot;&lt;i aria-hidden=\\&quot;true\\&quot; class=\\&quot;fa fa-search\\&quot;&gt;&lt;\\\/i&gt;&quot;,&quot;item_per_page&quot;:10,&quot;nav_style&quot;:&quot;both&quot;,&quot;prev_text&quot;:&quot;Prev&quot;,&quot;next_text&quot;:&quot;Next&quot;,&quot;prev_arrow&quot;:&quot;fas fa-long-arrow-alt-left&quot;,&quot;next_arrow&quot;:&quot;fas fa-long-arrow-alt-right&quot;}\">\n\t<table id=\"ekit-table-container-02c3478\" class=\"display dataTable\" style=\"width:100%\"><thead><tr>\t<th class=\"elementor-repeater-item-a90a945\">\n\t\t<div\n\t\t\tclass=\"ekit_table_item_container  ekit-table-container- \">\n\t\t\tCodice\t\t<\/div>\n\t<\/th>\n\t\t<th class=\"elementor-repeater-item-1a183bb\">\n\t\t<div\n\t\t\tclass=\"ekit_table_item_container  ekit-table-container- \">\n\t\t\tAllarme\t\t<\/div>\n\t<\/th>\n\t\t<th class=\"elementor-repeater-item-6904dd6\">\n\t\t<div\n\t\t\tclass=\"ekit_table_item_container  ekit-table-container- \">\n\t\t\tDescrizione\t\t<\/div>\n\t<\/th>\n\t\t<th class=\"elementor-repeater-item-12b0242\">\n\t\t<div\n\t\t\tclass=\"ekit_table_item_container  ekit-table-container- \">\n\t\t\tPossibile soluzione\t\t<\/div>\n\t<\/th>\n\t <\/tr><\/thead><tbody><tr>\t<td data-order=\"11\"\n\t\tclass=\"elementor-repeater-item-0562acd ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>11<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Voltage near the limit\"\n\t\tclass=\"elementor-repeater-item-d29edc7 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Voltage near the limit<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Loose tension is close to the set limit\"\n\t\tclass=\"elementor-repeater-item-1879453 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Loose tension is close to the set limit<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the values of the three phases: if they are close to the limit even when the inverter is off you need to check the transformer, if the phase values are close to the limit only when the inverter is running contact STI REPAIR service\"\n\t\tclass=\"elementor-repeater-item-092f336 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the values of the three phases: if they are close to the limit even when the inverter is off you need to check the transformer, if the phase values are close to the limit only when the inverter is running contact STI REPAIR service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"12\"\n\t\tclass=\"elementor-repeater-item-1fd43eb ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>12<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Degraded service\"\n\t\tclass=\"elementor-repeater-item-63f74ca ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Degraded service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"A module failed to activate after at least three attempts. The module was deactivated\"\n\t\tclass=\"elementor-repeater-item-2d79f6a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>A module failed to activate after at least three attempts. The module was deactivated <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"If the problem persists, contact STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-9c36e9a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>If the problem persists, contact STI REPAIR service.<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"13\"\n\t\tclass=\"elementor-repeater-item-7851b19 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>13<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Loss of DC insulation\"\n\t\tclass=\"elementor-repeater-item-3b4bb91 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Loss of DC insulation<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"An inverter insulation loss has been detected. The fuse of the \"grounding KIT\" has blown due to a current beyond its limit\"\n\t\tclass=\"elementor-repeater-item-fbbdb86 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>An inverter insulation loss has been detected. The fuse of the \"grounding KIT\" has blown due to a current beyond its limit <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the fuse of the grounding kit and replace it if it is blown. In case the new fuse blows immediately after the new replacement, contact STI REPAIR service department\"\n\t\tclass=\"elementor-repeater-item-4d7cde7 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the fuse of the grounding kit and replace it if it is blown. In case the new fuse blows immediately after the new replacement, contact STI REPAIR service department <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"14\"\n\t\tclass=\"elementor-repeater-item-e254842 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>14<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx AD Auto Zero KO\"\n\t\tclass=\"elementor-repeater-item-f2d4ac4 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx AD Auto Zero KO<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"The module motherboard has a problem in resetting the parameters\"\n\t\tclass=\"elementor-repeater-item-957c882 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>The module motherboard has a problem in resetting the parameters<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check all wire connections on the electronic boards of the modules. If problems persist, contact the STI REPAIR Service Department.\"\n\t\tclass=\"elementor-repeater-item-65c11f9 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check all wire connections on the electronic boards of the modules. If problems persist, contact the STI REPAIR Service Department. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"15\"\n\t\tclass=\"elementor-repeater-item-63e5784 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>15<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Alim KO 24V\"\n\t\tclass=\"elementor-repeater-item-5ef2541 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Alim KO 24V<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Lack of 24 V DC from the module's DC stack\"\n\t\tclass=\"elementor-repeater-item-8f9a34b ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Lack of 24 V DC from the module's DC stack<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the status of VAUX auxiliary switches (they must be closed) or the presence of the auxiliary line fed by the auxiliary transformer ***.\"\n\t\tclass=\"elementor-repeater-item-25bbab1 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the status of VAUX auxiliary switches (they must be closed) or the presence of the auxiliary line fed by the auxiliary transformer ***.<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"16\"\n\t\tclass=\"elementor-repeater-item-2eb1cf5 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>16<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Capacitor KO\"\n\t\tclass=\"elementor-repeater-item-0d36b54 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Capacitor KO<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"The module motherboard received an incorrect voltage value\"\n\t\tclass=\"elementor-repeater-item-a8ad850 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>The module motherboard received an incorrect voltage value<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check all wire connections on the electronic boards of the modules. If problems persist, contact the STI REPAIR Service Department.\"\n\t\tclass=\"elementor-repeater-item-d415e4a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check all wire connections on the electronic boards of the modules. If problems persist, contact the STI REPAIR Service Department. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"17\"\n\t\tclass=\"elementor-repeater-item-7316707 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>17<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxx no calibration\"\n\t\tclass=\"elementor-repeater-item-fd77370 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxx no calibration<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Problems with the calibration of the module motherboard\"\n\t\tclass=\"elementor-repeater-item-07d34c5 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Problems with the calibration of the module motherboard<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Contact STI REPAIR Service\"\n\t\tclass=\"elementor-repeater-item-46efcf7 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Contact STI REPAIR Service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"18\"\n\t\tclass=\"elementor-repeater-item-03acf6b ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>18<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx No configuration\"\n\t\tclass=\"elementor-repeater-item-254c32c ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx No configuration<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"No module configuration\"\n\t\tclass=\"elementor-repeater-item-688c081 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>No module configuration<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Contact STI REPAIR Service\"\n\t\tclass=\"elementor-repeater-item-c2aa811 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Contact STI REPAIR Service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"19\"\n\t\tclass=\"elementor-repeater-item-bfb7019 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>19<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Eeprom Modxxx Error\"\n\t\tclass=\"elementor-repeater-item-3ebf3b3 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Eeprom Modxxx Error<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Problems with motherboard eprom\"\n\t\tclass=\"elementor-repeater-item-2ad55ce ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Problems with motherboard eprom<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Contact STI REPAIR Service\"\n\t\tclass=\"elementor-repeater-item-32a29e4 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Contact STI REPAIR Service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"20\"\n\t\tclass=\"elementor-repeater-item-0a2f116 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>20<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overcurrent R\"\n\t\tclass=\"elementor-repeater-item-e09b20f ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overcurrent R<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Overcurrent in the first phase\"\n\t\tclass=\"elementor-repeater-item-789fa1d ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Overcurrent in the first phase<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-6c37404 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.  <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"21\"\n\t\tclass=\"elementor-repeater-item-911ae04 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>21<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overcurrent S\"\n\t\tclass=\"elementor-repeater-item-f0ef6aa ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overcurrent S<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Overcurrent in the second phase\"\n\t\tclass=\"elementor-repeater-item-c608825 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Overcurrent in the second phase<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-d2ce879 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.  <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"22\"\n\t\tclass=\"elementor-repeater-item-a007947 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>22<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overcurrent T\"\n\t\tclass=\"elementor-repeater-item-f353a1a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overcurrent T<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Overcurrent in the third phase\"\n\t\tclass=\"elementor-repeater-item-fb02e3f ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Overcurrent in the third phase<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-fff43fe ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the circuit breaker connections of the module in error but only to inform the STI REPAIR service of its main switchboard. If possible that the overcurrent was experienced by the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.  <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"23\"\n\t\tclass=\"elementor-repeater-item-4c617af ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>23<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overtemperature Mag1\"\n\t\tclass=\"elementor-repeater-item-d8711fb ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overtemperature Mag1<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Magnet (transformer) overtemperature- only if the inverter is equipped with it)\"\n\t\tclass=\"elementor-repeater-item-71e400a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Magnet (transformer) overtemperature<br \/>- only if the inverter is equipped with it)<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the connection labeled \"J17\" on the unit control board (not present on the R15015TL inverter or otherwise in transformerless inverters). If the cable coming from the temperature sensor (the red one) that is plugged into the magnet is well connected, the problem could be overtemperature. Contact STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-562589f ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the connection labeled \"J17\" on the unit control board (not present on the R15015TL inverter or otherwise in transformerless inverters). If the cable coming from the temperature sensor (the red one) that is plugged into the magnet is well connected, the problem could be overtemperature. Contact STI REPAIR service.  <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"24\"\n\t\tclass=\"elementor-repeater-item-cbfca24 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>24<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overtemperature Mag2\"\n\t\tclass=\"elementor-repeater-item-ae87331 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overtemperature Mag2<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Magnet overtemperature (inductance)\"\n\t\tclass=\"elementor-repeater-item-a3da2eb ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Magnet overtemperature (inductance)<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the connection marked \"J16\" on the unit control board. If the The cable coming from the temperature sensor (the gray one) that is plugged into the magnetic inductor is well connected, the problem may be overtemperature. Contact STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-fd1857e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the connection marked \"J16\" on the unit control board. If the The cable coming from the temperature sensor (the gray one) that is plugged into the magnetic inductor is well connected, the problem may be overtemperature. Contact STI REPAIR service.  <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"25\"\n\t\tclass=\"elementor-repeater-item-782271f ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>25<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx RS Overvoltage\"\n\t\tclass=\"elementor-repeater-item-57a3ba1 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx RS Overvoltage<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Measured overvoltage between phases RS\"\n\t\tclass=\"elementor-repeater-item-753b41b ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Measured overvoltage between phases RS<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-57f068e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"26\"\n\t\tclass=\"elementor-repeater-item-86d7446 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>26<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overvoltage ST\"\n\t\tclass=\"elementor-repeater-item-810bc74 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overvoltage ST<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Measured overvoltage between phases ST\"\n\t\tclass=\"elementor-repeater-item-7ef97d5 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Measured overvoltage between phases ST<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-9839d0c ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"27\"\n\t\tclass=\"elementor-repeater-item-5e3fb54 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>27<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overvoltage TR\"\n\t\tclass=\"elementor-repeater-item-f7953e2 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overvoltage TR<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Measured overvoltage between phases TR\"\n\t\tclass=\"elementor-repeater-item-3a934aa ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Measured overvoltage between phases TR<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-61f2c95 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced overvoltage from the inverter for a temporary surge. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"28\"\n\t\tclass=\"elementor-repeater-item-f249485 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>28<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx UDC Overvoltage\"\n\t\tclass=\"elementor-repeater-item-fceda94 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx UDC Overvoltage<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Overvoltage in DC voltage\"\n\t\tclass=\"elementor-repeater-item-b52aae5 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Overvoltage in DC voltage<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the VDC voltage value and if it is within the normal range (around 850-1320 Vdc) try restarting the inverter. In case the alarm occurs again, contact STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-8015c59 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the VDC voltage value and if it is within the normal range (around 850-1320 Vdc) try restarting the inverter. In case the alarm occurs again, contact STI REPAIR service. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"29\"\n\t\tclass=\"elementor-repeater-item-01d71f7 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>29<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Shutdown KO\"\n\t\tclass=\"elementor-repeater-item-ee50125 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Shutdown KO<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Problems in driving the module's DC stack\"\n\t\tclass=\"elementor-repeater-item-bc32c8d ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Problems in driving the module's DC stack<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the presence of the auxiliary line and\/or DC pack operation of the module: if both are ok contact STI REPAIR service\"\n\t\tclass=\"elementor-repeater-item-f24e790 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the presence of the auxiliary line and\/or DC pack operation of the module: if both are ok contact STI REPAIR service<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"30\"\n\t\tclass=\"elementor-repeater-item-042a5ed ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>30<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Ramp KO\"\n\t\tclass=\"elementor-repeater-item-9e5502e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Ramp KO<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Module fails to finish the startup procedure: problem reading values\"\n\t\tclass=\"elementor-repeater-item-ed6dcf9 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Module fails to finish the startup procedure: problem reading values<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check all wire connections on the electronic boards of the modules. If problems persist after a reboot, contact STI REPAIR Service.\"\n\t\tclass=\"elementor-repeater-item-31290ec ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check all wire connections on the electronic boards of the modules. If problems persist after a reboot, contact STI REPAIR Service. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"31\"\n\t\tclass=\"elementor-repeater-item-529cf71 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>31<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx IGBT KO\"\n\t\tclass=\"elementor-repeater-item-c62eab4 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx IGBT KO<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Module does not start due to problems in IGBT drivers: general alarm\"\n\t\tclass=\"elementor-repeater-item-630c37e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Module does not start due to problems in IGBT drivers: general alarm<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check all wire connections on the electronic boards of the modules. If problems persist after a reboot, contact STI REPAIR Service.\"\n\t\tclass=\"elementor-repeater-item-ef99229 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check all wire connections on the electronic boards of the modules. If problems persist after a reboot, contact STI REPAIR Service. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"32\"\n\t\tclass=\"elementor-repeater-item-080634d ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>32<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx has lost synchronicity\"\n\t\tclass=\"elementor-repeater-item-0a260fd ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx has lost synchronicity<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Connection problem between the Supervisor and the module motherboard.\"\n\t\tclass=\"elementor-repeater-item-b5dc996 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Connection problem between the Supervisor and the module motherboard.<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the connection between the modules electrical board and the supervisor, the cable whose connection check is the multicolor flat cable. If after verification the problem persists, contact STI REPAIR service department.\"\n\t\tclass=\"elementor-repeater-item-995a8a4 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the connection between the modules electrical board and the supervisor, the cable whose connection check is the multicolor flat cable. If after verification the problem persists, contact STI REPAIR service department. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"33\"\n\t\tclass=\"elementor-repeater-item-fe3ea5a ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>33<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx Overtemperature\"\n\t\tclass=\"elementor-repeater-item-5c42b27 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx Overtemperature<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Module temperature limit\"\n\t\tclass=\"elementor-repeater-item-c15620c ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Module temperature limit<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"The IGBT module has reached the temperature limit. Try a restart, but if the problem persists, contact STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-c7f012b ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>The IGBT module has reached the temperature limit. Try a restart, but if the problem persists, contact STI REPAIR service. <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"34\"\n\t\tclass=\"elementor-repeater-item-2b7538d ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>34<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx undervoltage RS\"\n\t\tclass=\"elementor-repeater-item-eb81115 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx undervoltage RS<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Undervoltage measured between phases RS\"\n\t\tclass=\"elementor-repeater-item-6dbf4d9 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Undervoltage measured between phases RS<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced undervoltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-dfbbcf6 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced undervoltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"35\"\n\t\tclass=\"elementor-repeater-item-8809d50 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>35<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx undervoltage ST\"\n\t\tclass=\"elementor-repeater-item-9f88f6e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx undervoltage ST<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Undervoltage measured between ST phases\"\n\t\tclass=\"elementor-repeater-item-7147f3e ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Undervoltage measured between ST phases<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced under voltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-9a65316 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced under voltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t<tr>\t<td data-order=\"36\"\n\t\tclass=\"elementor-repeater-item-cba59f9 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>36<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Modxxx undervoltage TR\"\n\t\tclass=\"elementor-repeater-item-f7ae0fe ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Modxxx undervoltage TR<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Undervoltage measured between phases TR\"\n\t\tclass=\"elementor-repeater-item-9f84c80 ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Undervoltage measured between phases TR<\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t\t<td data-order=\"Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced under voltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.\"\n\t\tclass=\"elementor-repeater-item-bde56df ekit_table_data_\">\n\t\t\n\t\t\t<div\n\t\t\t\tclass=\"ekit_table_body_container ekit_table_data_ ekit_body_align_left\">\n\t\t\t\t<p>Check the value of the three phases: it should be around 550Vac. In case the phase values are ok, check the circuit breaker connections of the module in error but only to inform the STI REPAIR service about its general status. If everything is okay, restart the inverter for a second try, you may have experienced under voltage from the inverter for a temporary spike. If the problem recurs, notify the STI REPAIR service.   <\/p>\n\t\t\t<\/div>\n\n\t\t\t\t<\/td>\n\t <\/tbody><\/table><\/div>\n\n\n\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-988d052 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"988d052\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>We provide the FIMER R Series Error Codes list, issued by the manufacturer, for an initial check on faulty inverter. It is recommended to scrupulously observe all safety regulations. <\/p>\n","protected":false},"author":3,"featured_media":17277,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-17660","page","type-page","status-publish","has-post-thumbnail","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Fimer R Series Error Codes<\/title>\n<meta name=\"description\" content=\"If your FIMER R Series inverter has anomaly and you need to understand the meaning here is the error message table.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fimer R Series Error Codes\" \/>\n<meta property=\"og:description\" content=\"We provide the FIMER R Series Error Codes list, issued by the manufacturer, for an initial check on faulty inverter. It is recommended to scrupulously observe all safety regulations. Get the most out of your energy - Repair, Regenerate, Swap\" \/>\n<meta property=\"og:url\" content=\"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/\" \/>\n<meta property=\"og:site_name\" content=\"STI Repair\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/it-it.facebook.com\/sticompany\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-18T15:05:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/STI_repair_Centralizzato_serie_R_diagnosi.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1900\" \/>\n\t<meta property=\"og:image:height\" content=\"1460\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/\",\"url\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/\",\"name\":\"Fimer R Series Error Codes\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/stirepair.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/STI_repair_Centralizzato_serie_R_diagnosi.webp\",\"datePublished\":\"2024-08-12T15:37:12+00:00\",\"dateModified\":\"2026-03-18T15:05:13+00:00\",\"description\":\"If your FIMER R Series inverter has anomaly and you need to understand the meaning here is the error message table.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/stirepair.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/STI_repair_Centralizzato_serie_R_diagnosi.webp\",\"contentUrl\":\"https:\\\/\\\/stirepair.com\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/STI_repair_Centralizzato_serie_R_diagnosi.webp\",\"width\":1900,\"height\":1460,\"caption\":\"FIMER R Series - Diagnosis\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/fimer-r-series-error-codes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/stirepair.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fimer R Series Error Codes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/stirepair.com\\\/en\\\/\",\"name\":\"STI Repair\",\"description\":\"Riparazione Inverter\",\"publisher\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#organization\"},\"alternateName\":\"STI\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/stirepair.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#organization\",\"name\":\"STI Repair\",\"url\":\"https:\\\/\\\/stirepair.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.stirepair.com\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/STI_Repair.png\",\"contentUrl\":\"https:\\\/\\\/www.stirepair.com\\\/wp-content\\\/uploads\\\/2022\\\/11\\\/STI_Repair.png\",\"width\":512,\"height\":512,\"caption\":\"STI Repair\"},\"image\":{\"@id\":\"https:\\\/\\\/stirepair.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/it-it.facebook.com\\\/sticompany\\\/\",\"https:\\\/\\\/it.linkedin.com\\\/showcase\\\/stirepair\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Fimer R Series Error Codes","description":"If your FIMER R Series inverter has anomaly and you need to understand the meaning here is the error message table.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/","og_locale":"en_US","og_type":"article","og_title":"Fimer R Series Error Codes","og_description":"We provide the FIMER R Series Error Codes list, issued by the manufacturer, for an initial check on faulty inverter. It is recommended to scrupulously observe all safety regulations. Get the most out of your energy - Repair, Regenerate, Swap","og_url":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/","og_site_name":"STI Repair","article_publisher":"https:\/\/it-it.facebook.com\/sticompany\/","article_modified_time":"2026-03-18T15:05:13+00:00","og_image":[{"width":1900,"height":1460,"url":"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/STI_repair_Centralizzato_serie_R_diagnosi.webp","type":"image\/webp"}],"twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/","url":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/","name":"Fimer R Series Error Codes","isPartOf":{"@id":"https:\/\/stirepair.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/#primaryimage"},"image":{"@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/#primaryimage"},"thumbnailUrl":"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/STI_repair_Centralizzato_serie_R_diagnosi.webp","datePublished":"2024-08-12T15:37:12+00:00","dateModified":"2026-03-18T15:05:13+00:00","description":"If your FIMER R Series inverter has anomaly and you need to understand the meaning here is the error message table.","breadcrumb":{"@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/#primaryimage","url":"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/STI_repair_Centralizzato_serie_R_diagnosi.webp","contentUrl":"https:\/\/stirepair.com\/wp-content\/uploads\/2024\/08\/STI_repair_Centralizzato_serie_R_diagnosi.webp","width":1900,"height":1460,"caption":"FIMER R Series - Diagnosis"},{"@type":"BreadcrumbList","@id":"https:\/\/stirepair.com\/en\/fimer-r-series-error-codes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/stirepair.com\/en\/"},{"@type":"ListItem","position":2,"name":"Fimer R Series Error Codes"}]},{"@type":"WebSite","@id":"https:\/\/stirepair.com\/en\/#website","url":"https:\/\/stirepair.com\/en\/","name":"STI Repair","description":"Riparazione Inverter","publisher":{"@id":"https:\/\/stirepair.com\/en\/#organization"},"alternateName":"STI","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/stirepair.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/stirepair.com\/en\/#organization","name":"STI Repair","url":"https:\/\/stirepair.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/stirepair.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.stirepair.com\/wp-content\/uploads\/2022\/11\/STI_Repair.png","contentUrl":"https:\/\/www.stirepair.com\/wp-content\/uploads\/2022\/11\/STI_Repair.png","width":512,"height":512,"caption":"STI Repair"},"image":{"@id":"https:\/\/stirepair.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/it-it.facebook.com\/sticompany\/","https:\/\/it.linkedin.com\/showcase\/stirepair"]}]}},"_links":{"self":[{"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/pages\/17660","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/comments?post=17660"}],"version-history":[{"count":2,"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/pages\/17660\/revisions"}],"predecessor-version":[{"id":19323,"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/pages\/17660\/revisions\/19323"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/media\/17277"}],"wp:attachment":[{"href":"https:\/\/stirepair.com\/en\/wp-json\/wp\/v2\/media?parent=17660"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}